Preventive
Maintenance
(Generator)
Maintenance on the generator end
is
minimal:
1.
Keep the generator clean, dry, and well-ventilated.
2.
Ensure that all connections are clean and tight, and that cables carrying AC voltage are properly sup-
ported and protected against chafing.
*3. The rear armature bearing is lubricated and sealed; no maintenance is required. However,
H the bear-
ing becomes noisy
or
rough-sounding, have it replaced.
Generator
Frequency
Adjustment
Frequency
is
a direct result
of
engine/generator speed, as indicated
by
the following:
When the generator
is
run at 1800 rpm, the AC voltage output frequency is 60 Hertz. When the generator is
run at 1500 rpm, the
AC voltage output frequency is 50 Hertz.
Therefore,
to
change the generator's frequency, the generator's speed must be changed.
To
accomplish
the frequency change, connect the
AC output leads
to
the AC terminal block in accordance wtth the "AC Vol-
tage Connections" diagram specified for your generator set, which appears in the "BC GENERATOR" sec-
tion
of
this manual, page 62.