BeG
4.0KW SYSTEM SPECIFICATIONS
AC
GENERATOR
General
Voltage
Rating (Volts AC)
60 Hertz (1800 rpm)
50 Hertz (1500 rpm)
AC Circuit Breaker
Generator
Cooling
Air Requirements, (60 Hertz),
at
1800 rpm
Brushless, four-pole, revolving
field.
Self
exciting. Capacitor saturated field excitation.
Pre-lubricated,
single-bearing design.
Reconnectable
120 Volls
or
120[240 Volts,
single-phase
120
or
120[240 Volts - 60 Hertz
220 Volts - 50 Hertz.
Voltage regulation:
±5%
no
load
to
full load.
Frequency regulation: ± 3 Hertz (5%)
no-load
to
fUll-load.
120 Volts
120[240 Volts
220 Volts
34
Amps
34[17
Amps
14
Amps
To
be rated at 120%
of
the generator's rated
amperage and voltage output.
225 elm (6.4 cmm)
NOTE: Increase air supply 15% for 50 Hertz operation (1500 rpm).
Engine Combustion Air
Requirements,
(60 Hertz),
at
1800 rpm
TUNE-UP
SPECIFICATIONS
Spark
Plug Gap
Contact Point Clearance
Timing
18
cfm
(0.509 cmm)
0.028 - 0.036 inches (0.70 - 0.90 mm)
0.016 - 0.020 inches (0.4 - 0.5 mm)
16'
±
l'
BTDC at 1800 rpm
13
Westerbeke
Generators
Comentarios a estos manuales