BCG S.5KW SYSTEM SPECIFICATIONS
AC
GENERATOR
General
Voltage
Rating (Volts
AC)
60 Hertz (1800 rpm)
50 Hertz (1500 rpm)
AC Circuit Breaker
Generator Cooling
Air Requirements, (60 Hertz),
at
1800 rpm
Brushless, four-pole, revolving field.
Self exciting. Capacitor saturated field excitation.
Pre-lubricated, single-bearing design.
Reconnectable 120
Volts
or
120/240 Volts,
single-phase
120
or
120/240 Volts - 60 Hertz
220
Volts - 50 Hertz.
Voltage regulation:
±5%
no
load
to
full load.
Frequency regulation:
± 3 Hertz (5%)
no-load
to
full-load.
120
Volts
120/240 Volts
220 Volts
54 Amps
54/27 Amps
27.8
Amps
To be rated at 120% of the generator's rated
amperage and voltage output.
250 cfm (6.23 cmm)
~:
Increase air supply 15%
for
50 Hertz operation (1500 rpm).
Engine Combustion Air
Requirements, (60 Hertz),
at
1800 rpm
TUNE-UP
SPECIFICATIONS
Spark
Plug Gap
Contact Point Clearance
Timing
32
clm
(0.906 cmm)
0.028 - 0.036 inches (0.70 - 0.90 mm)
0.016 - 0.020 inches (0.4 - 0.5 mm)
14° ±
BTDC at 1800 rpm
17