Generator
Mounting
-
Location
The complete generator unit is mounted on lightweight rails
by
means
of
four flexible isolator mounts that
help preventthe transfer of vibration from the generator
to
the rails. Each generator mounting rail has several
1/2-inch bolt holes
so
bolts can be employed
to
properly secure the generator
to
ks mounting platform.
These holes are on 15 inch mounting centers.
(1/2-
MOUNTING
HOLES)
The location should be dry, above low-lying vapor areas, and in an area where bilge water and water from
above cannot splash on the generator.
It should be properly ventilated and accessible
for
minor servicing
and repairs. Access
for
major repairs should be given consideration as well. The location should be proper-
ly ventilated
to
provide fresh cooling air for the generator end, for engine combustion needs, and
to
remove
heat produced
by
the engine while operating. The generator set needs fresh cool air in whatever location
in
the vessel it
is
installed. Hot generator discharge air
must
be removed from the generator area. The plat-
form on which the generator and
ks mounting rails are located should be strong enough
to
support the gen-
erator during all angles
of
vessel operation.
Westerbeke
Generators
20