Vista de pagina 14
BeG
II.OKW SYSTEM SPECIFICATIONS
Sea
Water Flow, at 1800 rpm
(measured before discharging
into exhaust elbow)
System Capacity (fresh water)
LUBRICATION SYSTEM
General
Oil Filter
Sump Capacity (not including filter)
Operating
Oil Pressure (engine hot)
Oil Grade
ELECTRICAL SYSTEM
Starting
Battery
Battery Capacity
DC Battery Charger
Starter
DC
No-Load Current
DC
Cranking Current
Westerbeke
Generators
3.75 -
11.0
U.S.
gpm
(14.19 - 15.14Ipm)
3.3
U.S.
qts (3.2 liters)
Pressure type by Trochoid pump,
chain-driven through balance shafts.
Full flow, paper element, spin-on type
3,0 qts (2.9 liters)
50
- 70 psi (3.5 - 4.9 kg/cm
2
)
API
specification of
SD
or
SE,
preferably SF
12-Volt,
26 A-H,
(-)
negative ground
(recommended)
(35
A-H in cold areas)
90
- 125 (Ampere-Hours)
Internal regulator
13
Volts, 0
-10
Amps.
12-Volt,
1.2f<W,
reduction type,
solenoid-mounted
90
Amp (max,) at 11.5 Volts.
175 - 200 Amps (engine cold)
12
Vista de pagina 14