Trouble
Engine starts, runs and then
shuts down.
Back firing through carburetor.
Engine overheats.
67
Possible Cause
1.
Faulty automatic shutdown switch
(oil, water,
or
eXhaust).
2.
Faulty overspeed switch (reset and start;
bypass
SWITch
to
test).
3.
Faulty fuel pump.
4.
Faulty STOP switch.
5.
Engine circutt breaker
is
tripping.
6.
Dirty fuel filters.
7.
Low oil level in sump.
8.
Mechanical check valve at the fuel supply
fuel pump
is
unable
to
draw
fuel through this valve.
1.
Ignition timing is wrong.
2.
Engine is flooded.
3.
Choke
is
stuck closed.
4.
Spark plug wires are connected wrong
--
check firing order.
5.
Distributor cap is cracked.
6.
Dirty air cleaner.
1.
Coolant loss (pressure test the cooling system).
2.
Belts are loose
or
broken.
3.
Sea water pump's impeller
is
faulty.
4.
Sea water pump is worn.
5.
Faulty hose.
6.
Thermostat
is
stuck closed.
7.
Heat exchanger
is
clogged.
8.
Faulty gauge (check with a thermometer).