Description
of
Starting System
Westerbeke diesel engines use electric starters assisted
by
glow plugs
for
both normal and cold weather
starting. The figure below shows a cross-sectional view of one cylinder. The glow plug is located in the com-
bustion chamber so that its tip is in the injector nozzle's spray path. When the
glow
plug is energized
by
the
PREHEAT button, the plug glows red at the
tip
and assists in igniting the fuel. The result is a rapid start with
less wear on the starter.
This system is common
to
Westerbeke Diesels. The start circuitry is designed so that the PREHEAT button
must be depressed
for
the time specified in the "Preheat" chart shown on page 33. Then, while keeping the
PREHEAT button engaged, the START button is depressed
to
crank the engine.
Combustion
Chamber
NOTE: The START switch will not energize unless the PREHEAT button is depressed. When
depressing the preheat switch,
we
are activating the
glow
plugs in the cylinder head,
so
use
the preheat intermittently so as not
to
overheat the glow plugs.