ALTERNATORS
TESTING/TROUBLESHOOTING
TESTING
THE
EXCITATION
CIRCUIT
1.
Connect
the
positive(+) multimeter probe
to
the
excitation terminal R
on
the
alternator
and
the
negative
(-) lead
to
ground.
2.
Turn the battery switch to the on position
and
note
the multimeter reading. The reading should
be
1.3
to
2.5
volts (see illustration).
TESTING
THE
EXCITATION
CIRCUJT
(IGNITION
3.
If
the reading
is
between .75 and
1.1
volts,
the
rotor
field
circuit probably
is
shorted
or
_grpunded.
4.
If
the
readin~
is
between 6.0
and
7.0
V()lts,
the rotor
field
circuit probably
is
open.
5.
If
no reading is obtained,
an
open exists
in
the
alternator-excitation lead or
in
the
excitation circuit of
the regulator. Disconnect the lead from
exc.
terminal
R.
Connect
the
·positive multimeter probe
to
the
excitation
lead
and
the
negative multimeter probe
to
ground.
If
the multimeter
now
indicates
an
approximate battery
voltage, the voltage regulator
is
defective
and
must be
replaced.
If
no
voltage.is indicated, check the
excitation circuit
for
loose or dirty connections or
damaged wiring.
REMOVE
TERMINALR
TESTING
THE
EXCITATI.ON
CIRCUIT
(IGNITION
ON)
CHECKING
THE
SERVICE
BATTERY
Check
the
voltage
of
the
service
battery.
this
battery
should
have
a
voltage
between
13
and
14
volts
when
the
engine
is
running.
If
not,
there
is
a problem
jn
the
service
battery
charging
circuit.
Troubleshoot-the
service
battery
charging
circuit
by
checking
the
wiring
and
connections,
the
solenoid,
isolator,
battery
switch,
and
the
battery itself.
When
the
problem
has
been
solved
and
before
the
alternator
is
back
in
operation, take
the
time
to
tighten
and
clean
the
terminal
studs.
Also
clean
the
connecting
terminals
from
the
wiring
harness.
ALTERNATOR
REPAIR
If
tests
indicate a failed
alternator,
it
will
need
to
be
disas-
sembled
and
repaired.
Any
good
alternator
service
shop
can
do
the
job.
NOTE:
WESTERBEKE'S service
Manual
has detailed
instructions for
the
disassembly and repair
of
their
standard alternators.
BATTERY
CARE
The
minimum
recommended capacity of
the
battery
used
in
the
engine's
12
volt
DC
control circuit
is
600-900
<:;old
Cranking
Amps
(CCA).
Review
the manufacturer's
recommendations
and
the!}
establish a
systematic
maintenance schedule
for
your
engine's starting batteries
and
house
batteries.
Monitor your voltmeter
for
proper
charging
during
engine
operation.
Check
the
electrolyte level
and
specific
gravity
with
a
hydrometer.
Use
only
distilled water
to
bring electrolytes
io
a
proper
level.
Make
certain that battery cable
connections
are
clean
and
tight
to
the
battery posts (and
to
your
engine).
Keep your batteries clean
and
free
of
corrosion.
A
CAUTION:
Before
starting
the
engine
make
certain
that
everyone
is
clear
of
moving
parts!
Keep
away
from
sheaves
and
belts
during
test
procedures.
A
CAUTION:
To
avoid
damage
to
the
battery
charging
circuit,
never
shut
off
the
engine
battery
switch
when
the
engine
is
running!