ENGINE TROUBLESHOOTING
Introduction
The tables which follow Indicate troubleshooting procedures based upon certain problem indicators, the
probable causes
of
the problems, and the recommendations
to
overcome these problems.
Note that the engine's control system (electrical system) is protected by a 20-Ampere manual reset circuit
breaker located on the rear lifting bracket.
problem
PREHEAT button is de-
pressed: no panel in-
dications.
START button
is
de-
pressed:
no
starter
engagement.
Westerbeke
Diesel
Engines
probable Cause
Battery switch or
Circuit Breaker
is
not ON.
20-Amp circutt
breaker has tripped.
Must PREHEAT first.
Connection
to
the
solenoid
is
faulty.
FaUlty START switch.
Faulty solenoid.
54
Verification/Remedy
Check the
swttch, Breaker and!
or the battery connections.
Reset breaker;
H the breaker
trips again, check the preheat
solenoid
circutt and circuit for
shorts.
PREHEAT button must be
depressed
to
activate the
START button.
Check the connection.
Check the switch with an
ohmmeter.
Check that
12
Volts is present
at the solenoid connection on
the starter.