Westerbeke WPDS-20 Manual del operador Pagina 36

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 114
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 35
DESCRIPTION OF INSTRUMENT PANEL
Westerbeke
40NA engines are supplied with instrument panels. Read the following instruction carefully
before operating the engine.
RPM
Gauge
Water
Temperature
Gauge
Oil
Pressure
Gauge
Ammeter
.
Vo~age
Gauge
General
The manually-controlled panel
is
equipped with an
RPM
gauge with an ELAPSED TIME meter which measures
the engine's running time in
HOURS and in 1/10 hours. The panel also includes a water temperature gauge
which indicates watertemperature in degrees Fahrenheit
(WATER
0
F),
an oil pressure gauge which measures
the engine's oil pressure
in
pounds per square inch (OIL PSI), a
DC
control circuit voltage gauge which
measures the system's
DC
voltage (VOLTS), and a DC Ammeter which allows the operator
to
monitor
amperage in the
DC
charging circuit. All gauges are illuminated when the circuit breaker is turned ON and
remain illuminated while the engine is in operation. The
panel also contains
two
rubber-booted push but-
tons, one for PREHEAT and one for
START.
1.
Circuit Breaker (Not Shown): The Circuit Breaker, positioned somewhere
in
the vessel so it may be
easily reached, provides power
only
to
the instrument cluster. Refer
to
the "STOPPING PROCEDURE"
section
of
this manual, page
28.
2.
PREHEAT: The PREHEAT button energizes the alternator's EXC terminal and the intake manifold's
thermostart device. This button also energizes the
START
button.
3.
SIABI.:
The START button, when pressed, energizes the starter's solenoid which cranks the engine.
This button
will not operate electrically unless the PREHEAT button is pressed and held at the same
time.
Westerbeke
Diesel
Engines
24
Vista de pagina 35