  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
Be
GENERATOR
SINGLE
PHASE
NOTE:
WESTERBEKE recommends that the following generator tests
and adjustments be performed
by
a qualified
technician.
INTEGRAL
CONTROLLER
(I.C.)
Testing
the
Battery
Charging
Circuit
The Integral Controller (I.C)
is
an
encapsulated, solid-state
unit that supplies a
DC
charging voltage
to
the generator's
starting battery while the generator
is
opening.
Charging Voltage: 13.0 - 14.0 volts DC
Charging Amperage: 0 - 10- amps DC
A separate group
of
stator windings supplies AC voltage
to
a
bridge rectifier which converts the
AC
current
to
supply
the
I.C
unit. The
I.C
unit senses the needs of the starting battery
and
supplies a DC charge when
one
is needed. If
you
suspect .
that
the
I.e.
unit is faulty (that is, if
the
battery's charge
is
low), check
the
charging circuit
and
it's components
as
described
in
the following steps. Check
all
connections for
cleanliness
and
tightness including the ground before replac-
ing the
I.C
unit.
NOTE:
When
the
generator
is
first
started,
the
I.C
unit will
produce a low charging
rate.
This
charging rate will
rise
as
the generator
is
operated.
The Integral Controller is mounted inside the generator hous-
ing
in
the 12:00 position. There
is
a voltage output adjust-
ment
on
the controller that will allow a DC voltage output
adjustment
of
± 2 volts.
+
GND
BLACK
VOLTAGE
OUTPUT
ADJUSTMENT
(ON
BACK)
YELLOW
GROUND
TO
GENERATOR
CASE
AC
BRIDGE
RECTIFIER
1.
Bridge Rectifier
Normal AC voltage running
to
the rectifier (while the
engine
is
operating
at
1800
rpm)
is
measured
across the
two
AC
connections
on
the
bridge
rectifier.
(As
illustrated).
AC voltage running
to
the
bridge rectifier (approximate):
No-load off the generator 16.0 volts AC
Full-load off the generator 17.5 volts AC
Normal DC voltage running but
of
the
rectifier
(in
volts
DC) is measured across
the
two
DC connections
of
the
bridge rectifier; that
is
+
and
-.
DC voltage running
from
the bridge rectifier
(approximate):
No-load
off
the generator
Full-load off the generator
2.
AC
winding: 0.14 ohm
17.0 volts DC
18.5 volts DC
Lift
the
two
AC wire leads off the bridge rectifier
and
measure,
the
resistance between these
two
leads
with
an
ohmmeter.
It
should measure 0.14 ohm.
No
continuity
should exist between these two leads
and
the
ground
or
the
main
AC stator windings.
3. Testing the Bridge Rectifier (meter
used
- Simpson 260)
A Set your ohmmeter's scale
on
RX1
(+
DC)
and set the
needle
to
zero.
B. Connect the (+) positive lead
from
the
ohmmeter
to
point #4. Taking
the
ohmmeter's negative (-)
lead,
momentarily touch points #1, #2, #3,
and
#5.
The ohm-
meter should register
no
deflection
for
any
of
the
points touched.
C. Remove the positive
(+)
lead
from
point
#4
and
connect the negative (-) lead; momentarily touch
'points
#1,
#2,
and
#3.
The ohmmeter's needle should
deflect
when
each
point is touched.
D.
Leaving the negative ohmmeter
(-)
lead
on
point #4,
touch point #5
with
the
positive
lead.
No
deflection
should take place.
E. Place
.the
positive
(+)
lead
on point
#1
and
the
negative
(-)
lead
on
point
#3.
The ohmmeter
again
should
not
register
any
deflection'(no deflection indicated infinite
resistance). Reverse these connections
and
the
ohmme-
ter should again register
no
deflection. If
the
rectifier
fails any of
the
previous tests (A-E), replace the recti-
fier
because it
is
defective.
NOTE:
l)ifferent types
and/or
brands
of
test
meters
may
produce opposite test
results.
POINT
i/4
POINT
#5
MOUNTING
HOLE
Engines & Generators
BRIDGE
RECTIFIER
35