ELECTRICAL SYSTEM
WARNING:
An improper ground can cause severe
personal injury or death from fire or explosion. Be sure
to install a common ground conductor between all on-
board cranking circuits.
WARNING:
The ignition of gasoline fuel or fumes
can result in severe personal injury or death. Connect
the engine/generator battery ground lead only at the
location shown.
A common ground for (–) negative DC is located at the
bellhousing of the engine/generator next to the starter in the
form of a threaded grounding stud. This location is tagged. It
is recommended that the battery ground be connected here.
Failure to do so can cause arcing or resistance in the cranking
circuit.
Connect battery (+) positive to the starter solenoid terminal
tagged for this connection.
The DC power source for the generator can be obtained from
the main engine’s starting battery. A battery disconnect switch
should be installed in the B+ battery cable to the generator.