Generator
M()urlllrig
- localion
com,llel:e
fl,nemlor
unIT
Is
mounted
011
rails means
01
four flexible isolator mounts thai
tr~n"fA'
of vibration from the rails. Each
rail
has several
1/2-lnch boll holes so bolts can be employed to properly secure the
ne,ner'atCl(
These holes are on
15
inch centers.
(1!2~
MOUMTIMG
HOLES)
The location should be dry, above low-lying vapor areas, and away from splashed by bilge water or
water
from above. It should be property ventilated and accessible for minor servicing and repairs. Access
for major repairs should be given consideration
as
well. The location should
be
properly ventilated
to
provide
fresh cooling
air for the generator
end,
lor
engine combustion needs, and
10
remove heat produced by the
engine while operating. The generator set needs Iresh cool air
in
whatever location
in
the vessel it
is
installed.
Hot generator discharge air must be removed from the generator area. The platform on which the gener·
ator and its mounting rails are localed should
be
slrong
to
support the generator during
all
angles
of vessel operation.
Weslerbeke Generators