BTG
ItS
KW
SYSTEM
SPECIFICATIONS
AC
GENERATOR
General
Rating (Volts AC)
60
Hertz (1800 rpm)
50
Hertz (1500 rpm)
AC Circuit Breaker
Generator
Cooling
Air Requirements, (60 Hertz),
at
1800
rpm
Brushless, revolving field.
Pre-lubricated, single-bearing design.
Reconnectable, single-phase transformer regulation
(optional solid-state voltage regulation).
120
or
120/240 Volts -
60
Hertz
220 Volts -
50
Hertz.
Voltage regulation:
± 5%
no
load
to
full load.
Frequency regulation: ± 3 Hertz (5%)
no-load
to
full-load.
120 Volts
120/240 Volts
220 Volts
70 Amps
70/35 Amps
31
Amps
To
be
rated at 120%
of
the generator's rated
amperage
output
and
voltage
200
- 225 elm (5.7 -
6.4
cmm)
NOTE: Increase air
supply
15%
lor
50 Hertz operation (1500 rpm).
Engine Combustion Air
Requirements,
(60 Hertz),
at 1800 rpm
TUNE-UP
SPECIFICATIONS
Spark Plug
Gap
35 elm (1.0 cmm)
0.031 ± 0.002 inches (0.80 ± 0.05 mm)
14° ±
1°
BTDC at 1800 rpm
15
Weslerbeke
Generators
Comentarios a estos manuales