4.5 KW BCG SYSTEM SPECIFICATIONS
AC
GENERATOR
General
Voltage
Rating (volts
AC)
60 Hertz (1800 rpm)
50 Hertz (1500 rpm)
AC Circuit Breaker
Generator Cooling
Air Requirements,
(60
hertz).
at
1800 rpm
Brushless, four-pole, revolving field.
Self exciting. Capacitor saturated field excitation.
Pre-lubricated, single-bearing design.
Reconnectable
120 volts
or
120/240 volts,
single-phase.
120 or 120/240 volts - 60 hertz
220 volts - 50 hertz.
Voltage regulation:
± 5% no-load
to
full-load.
Frequency regulation:
± 3 hertz
(5%)
no-load
to
full-load.
120 volts
120/240 volts
220 volts
37.5 amps
37.5/18.7 amps
16 amps
To
be rated at 120% of the generator's rated
amperage and voltage output.
225 - 240 cfm (6.4 - 6.6 cmm)
MQIE.: Increase air supply 15% for 50 hertz operation (1500 rpm).
Engine Combustion Air
Requirements,
(60
hertz),
at
1800 rpm
TUNE-UP SPECIFICATIONS
Spark Plug
Gap
Contact
Point Clearance
Timing
Dwell Angle
18 cfm (0.509 cmm)
0.028 - 0.031 inches (0.70 - 0.80 mm)
0.017 - 0.018 inches (0.4 - 0.5 mm)
11'
±
.5'
BTDC at 1800 rpm
58 -
66'
11
Westerbeke Generators
Comentarios a estos manuales