Load Applied
4-Pole Speed
Frequency
Generator Voltage
(rpm) (Hertz)
120V (110) 240V (220)
Plants Plants
None
1830 62
122
240
(1530) (52)
(ll2)
(224)
Half
1800
60 120
240
(1500) (50) (110) (220)
Full 1755 59 110 220
(1455) (49) (100) (200)
The output voltage should be checked periodically to ensure proper operation
of
the generating plant and
the appliances it supplies.
If
an
AC
voltmeter or ampmeter is not installed to monitor voltage and load, check it with a portable
meter and amp-probe.
Preventive
Maintenance
(Generator)
Maintenance on the generator is minimal.
1.
Keep the generator clean,
dry
and
well-ventilated.
2.
Ensure that all connections are clean and tight and that cables carrying AC voltage are properly
supported and protected against chafing.
3.
The rear armature bearing
is
lubricated and sealed; therefore,
no
maintenance is required.
If
the
bearing becomes rough or noisy, replace it.
Generator
Troubleshooting
A complete and illustrated test on troubleshooting the
BID
series
of
generators is furnished in the
Technical Manual which is available through your local dealer.
WESTERBEKE
GENERATORS
58