STOPPING
PROCEDURE
1.
Remove the AC electrical loaf from the generator and allow the generator
to
run for 3 to 5 minutes to
stabilize its operating temperature.
2.
Depress the STOP switch and hold it until the generator is completely stopped.
3.
Now release the STOP switch.
Remote Stopping
Procedure
To stop the generator, depress the STOP switch which opens the normally closed B+ path for voltage to
the engine's run circuit. The bright green LED will
go
dim/faint when the generator slows and stops.
Then it will
go
out, indicating the engine has stopped. The STOP switch must be held open until the
generator comes
to
a complete stop. Remote start panels may be connected
to
the generator set as
indicated. A jumper has to be removed between the T
-1
and T -2 connections
at
the panel connection
terminal board. (Refer to the wiring diagram in the "ELECTRICAL
SYSTEM" section
of
this manual for
remote start/stop panel connections.)